Protecting Cased Pipeline Crossings Two cased pipeline crossings in the Middle East needed protection against corrosion inside the annular space between the carrier pipeline and the casing. This area was a catchpoint for moisture and debris that could accelerate corrosion and threaten pipeline integrity.

After installing new vents, reducers, and end seals, workers flushed the casings out twice with VpCI®-649 BD treated water. Water was suctioned out, and the casing was pressure tested. Finally, CorroLogic® VpCI® Filler Part A and Part B were pumped into the casing to fill the annular space with a gel containing a high dose of Vapor phase Corrosion Inhibitors. Electrical resistance probes were installed for future corrosion monitoring.

The treatment was considered an effective and cost-saving means of protecting and extending the service life of these two cased pipeline crossings. This approach has now been used both in North America and Saudi Arabia.