CASE HISTORY SPOTLIGHT: Case History #598: Closed-Loop Cleaning and Preservation on Private Yacht

CASE HISTORY SPOTLIGHT: Case History #598: Closed-Loop Cleaning and Preservation on Private Yacht June 23, 2021 One of the world’s largest privately-owned yachts was taken to France for maintenance and repair. The pipes of the VACON drives needed to be cleaned from heavy scale in a very short timeframe. [...]

By |2022-09-29T07:01:36-05:00September 29th, 2022|Case History Spotlight|Comments Off on CASE HISTORY SPOTLIGHT: Case History #598: Closed-Loop Cleaning and Preservation on Private Yacht

CASE HISTORY SPOTLIGHT: Case History #749: Prevention of New Firetube Boiler Corrosion

CASE HISTORY SPOTLIGHT: Case History #749: Prevention of New Firetube Boiler Corrosion June 23, 2021 Every month, a leading manufacturer of Scotch Marine Firetube boilers typically ships one or two boilers overseas or to customers that cannot immediately install the boilers. For more than a decade, the manufacturer has [...]

By |2022-09-21T08:33:19-05:00September 21st, 2022|Case History Spotlight|Comments Off on CASE HISTORY SPOTLIGHT: Case History #749: Prevention of New Firetube Boiler Corrosion

CASE HISTORY SPOTLIGHT: Case History #500: Steam Turbine and Boiler System Preservation

CASE HISTORY SPOTLIGHT: Case History #500: Steam Turbine and Boiler System Preservation September 13, 2022 A power plant in Alaska needed to shut down and preserve its Unit 8 steam turbine, boiler system, and associated piping for three years. To do so, all access ports were first closed and [...]

By |2022-09-13T03:09:56-05:00September 13th, 2022|Case History Spotlight|Comments Off on CASE HISTORY SPOTLIGHT: Case History #500: Steam Turbine and Boiler System Preservation

CASE HISTORY SPOTLIGHT: Case History #479: Outdoor Boiler Tube Preservation

CASE HISTORY SPOTLIGHT: Case History #479: Outdoor Boiler Tube Preservation September 8, 2022 Two spare boiler tube bundles needed preservation against corrosion in harsh outdoor storage conditions while remaining ready for use at any time. To prep the bundles for storage, loose rust and debris were blown off with [...]

By |2022-09-08T02:53:13-05:00September 8th, 2022|Case History Spotlight|Comments Off on CASE HISTORY SPOTLIGHT: Case History #479: Outdoor Boiler Tube Preservation

CASE HISTORY SPOTLIGHT: Case History #314: Parking Garage Restoration

CASE HISTORY SPOTLIGHT: Case History #314: Parking Garage Restoration September 01, 2022  A medical center parking garage in Ohio had corrosion problems in its top precast slab, requiring partial to full repair. MCI®-2005 NS was added to new parts of the slab to mitigate corrosion of existing steel and [...]

By |2022-09-01T02:55:45-05:00September 1st, 2022|Case History Spotlight|Comments Off on CASE HISTORY SPOTLIGHT: Case History #314: Parking Garage Restoration

CASE HISTORY SPOTLIGHT: Case History #253: Condo Balcony Repair

CASE HISTORY SPOTLIGHT: Case History #253: Condo Balcony Repair August 18, 2022 As part of a balcony repair project, a condominium complex in Cincinnati needed overhead patching and caulking followed by a sealer. Cortec® MCI®-2019 was chosen for the latter as a two-in-one Migrating Corrosion Inhibitor™ / water repellent [...]

By |2022-08-18T10:51:34-05:00August 18th, 2022|Case History Spotlight|Comments Off on CASE HISTORY SPOTLIGHT: Case History #253: Condo Balcony Repair

CASE HISTORY SPOTLIGHT: Case History #121: Plankinton Avenue Parking Ramp Preservation

CASE HISTORY SPOTLIGHT:  Case History #121: Plankinton Avenue Parking Ramp Preservation August 10, 2022 In 1999, the Plankinton Avenue parking ramp in downtown Milwaukee was deteriorating and rebar had rusted in the concrete due to deicing salt. The city wanted an economical way to renovate and protect the ramp [...]

By |2022-08-10T08:39:05-05:00August 10th, 2022|Case History Spotlight|Comments Off on CASE HISTORY SPOTLIGHT: Case History #121: Plankinton Avenue Parking Ramp Preservation

CASE HISTORY SPOTLIGHT: Case History #400: Clean, Dry Corrosion Protection for Foundry Parts

CASE HISTORY SPOTLIGHT: Case History #400: Clean, Dry Corrosion Protection for Foundry Parts July 27, 2022 A foundry in India wanted to protect metal components from rust in a clean and dry manner so they would be ready to use out of the box without cleaning. VpCI®-369N5 was applied [...]

By |2022-07-27T02:44:57-05:00July 27th, 2022|Case History Spotlight|Comments Off on CASE HISTORY SPOTLIGHT: Case History #400: Clean, Dry Corrosion Protection for Foundry Parts

CASE HISTORY SPOTLIGHT: Case History #78: Corrosion Protection of Nuclear Power Company Spares

CASE HISTORY SPOTLIGHT: Case History #78: Corrosion Protection of Nuclear Power Company Spares July 19, 2022 A nuclear power company needed corrosion protection for two hundred million dollars’ worth of spare parts, electronics, and facilities in storage. They used VpCI®-389 to protect sensitive parts of the backup diesel power [...]

By |2022-07-19T03:27:11-05:00July 19th, 2022|Case History Spotlight|Comments Off on CASE HISTORY SPOTLIGHT: Case History #78: Corrosion Protection of Nuclear Power Company Spares

CASE HISTORY SPOTLIGHT: Case History #716: Corrosion Protection of Brake Rotors

CASE HISTORY SPOTLIGHT: Case History #716: Corrosion Protection of Brake Rotors July 14, 2022 It has been about 15 years since one brake rotor manufacturer stopped using liquid rust preventatives for the WIP (work-in-process) cycle and started sandwiching parts between precut sheets of CorShield® VpCI®-146 Paper. This provided satisfactory [...]

By |2022-07-14T06:43:46-05:00July 14th, 2022|Case History Spotlight|Comments Off on CASE HISTORY SPOTLIGHT: Case History #716: Corrosion Protection of Brake Rotors
Go to Top