Approximate Dosing for Cortec Hydrotesting Additives
Approximate Dosing for Fresh Water Additive
|
Product |
Metals Protected |
During Testing |
1-3 Months |
6-12 Months* |
12-24 Months* |
VpCI-641 |
Multimetal |
500-750pppm |
1000ppm |
- |
- |
VpCI-611 |
Ferrous, aluminum, galvanized steel, NO YELLOW |
2.5-10wt% |
5-10 wt% |
10-15 wt% |
20wt% |
VpCI-609 |
Ferrous, aluminum, galvanized steel, NO YELLOW |
0.5-1wt% |
1-1.5 wt% |
5 wt% |
5 -10wt% |
VpCI-308 |
Multimetal |
0.5-1wt% |
1-1.5 wt% |
3-5 wt% |
5-10wt% |
Versions of S-69 and VpCI-649 |
Multimetal |
0.3-0.5wt% |
0.5-1wt% |
0.5-1wt% |
0.6-1wt% |
VpCI-649 Powder and S-69 Powder |
Multimetal |
0.2-0.35% |
0.35-0.7% |
0.35-0.7% |
0.4-0.7% |
VpCI-377 |
Multimetal |
0.5-0.75wt% |
0.5-1wt% |
2-3 wt% |
3-5wt% |
Approximate Dosing for Cast Iron in Fresh Water
|
Product |
Metals Protected |
During Testing |
1-3 Months |
6-12 Months* |
12-24 Months* |
VpCI-609 |
Cast Iron |
1.5-2.5 wt% |
- |
- |
- |
VpCI-611 |
Cast Iron |
10-12.5 wt% |
10-15wt% |
10-20wt% |
20wt% |
VpCI-417P |
Cast Iron |
0.2 wt% |
0.2- 0.5wt% |
0.5-1wt% |
1-2wt% |
S-69P |
Cast Iron |
0.75-2wt% |
5wt% |
5-7 wt% |
7wt% |
M-370 |
Cast Iron |
5wt% |
10wt% |
10wt% |
10wt% |
M-640L |
Cast Iron |
2.5wt% |
5wt% |
5wt% |
NE |
M-95 |
Cast Iron |
2.5wt% |
5wt% |
5wt% |
NE |
Approximate Dosing for Brines Additives TDS <0.5wt%, CL<0.1wt%
|
Product |
Metals Protected |
During Testing |
1-3 Months |
6-12 Months* |
12-24 Months* |
VpCI-644 |
Multimetal |
0.2wt% |
- |
- |
- |
VpCI-645 |
Multimetal |
0.5wt% |
- |
- |
- |
VpCI-611 |
Ferrous, aluminum, galvanized steel, NO YELLOW |
5wt% |
5wt% |
- |
- |
VpCI-609 |
Ferrous, aluminum, galvanized steel, NO YELLOW |
1-3wt% |
1-3wt% |
5- 10 wt% |
- |
M-645 |
Multimetal |
Dosage based |
on area to be |
protected |
1250 ft2/gal (30.7m2/L)- |
Versions of S-69 and VpCI-649 |
Multimetal |
0.5-1wt% |
0.5-1wt% |
- |
- |
Approximate Dosing for Sea Water Additives
|
Product |
Metals Protected |
During Testing |
1-3 Months |
6-12 Months* |
12-24 Months* |
VpCI-644 |
Multimetal |
0.3-0.5wt% |
0.75-1wt% |
- |
- |
VpCI-645 |
Multimetal |
0.75-1wt% |
0.75-1wt% |
- |
- |
S-69P |
Multimetal |
5wt% |
5wt% |
- |
- |
VpCI-611 |
Ferrous,aluminum, galvanized steel, NO YELLOW |
5wt% |
5wt% |
- |
- |
M-645 or Ecoline 3220 |
Multimetal |
Dosage based |
on area to be |
protected |
1250 ft2/gal (30.7m2/L)- |
Note: Solutions can be reused, provided the concentration level of each is checked before reuse. *For long term protection after hydrotesting, it is best to drain sytem well and use additional fogging of VpCI material or rinse with a long term corrosion inhibitor in tap water. Additionally, an inspection should be performed every 6-12 months and VpCI should be reapplied if needed. Long term protection may vary due to condition of metal and sealing of vessel. |