Corrosion Additives for Shell Corena De Compressor Oil
Purpose: Determine compatibility of Cortec Corrosion inhibiting additives with Shell Corena DE compressor oil.
Materials: Shell Corena DE compressor oil
M-529
VpCI-326
VpCI-322
Method: Standardized Compatibility Test
Procedure: The following samples were created:
Sample |
Base Oil |
(Percent by weight) |
Cortec Oil |
(Percent by weight) |
A1 |
Shell Corena DE |
97 |
M-529 |
3 |
B1 |
Shell Corena DE |
95 |
M-529 |
5 |
C1 |
Shell Corena DE |
90 |
M-529 |
10 |
D1 |
Shell Corena DE |
90 |
VpCI-322 |
10 |
E1 |
Shell Corena DE |
90 |
VpCI-326 |
10 |
The following procedure was followed:
-
- The samples were mixed and observed
- Compatibility is rated as a homogenous mixture with no gelling, precipitates, adverse reactions, or other deleterious affects
- The sample is listed as ok if considered compatible.
- The samples are cycled, 8 hours at 0° C and 16 hours 50° C, and observed at the different intervals. This is considered one cycle and the test is three cycles in duration.
- The samples were mixed and observed
Results: The following results were found:
Compatibility |
|||||||
Sample |
Initial |
8 hours |
24 hours |
32 hours |
48 hours |
56 hours |
72 hours |
A1 |
ok |
ok |
ok |
ok |
ok |
ok |
ok |
B1 |
ok |
ok |
ok |
ok |
ok |
ok |
ok |
C1 |
ok |
ok |
ok |
ok |
ok |
ok |
ok |
D1 |
ok |
ok |
ok |
ok |
ok |
ok |
ok |
E1 |
ok |
ok |
ok |
ok |
ok |
ok |
ok |
Conclusion: Shell Corena DE compressor oil is considered compatible with M-529, VpCI-322, and VpCI-326 at the concentrations listed above.
Project #: 02-203-1325
Estimated Cost of Project: 2.5 hours
To: Mark Richler, Israel Richler Trading Ltd
From: Brian L. Wuertz
Date: 09-16-2002
cc: Boris Miksic
Anna Vignetti
Art Ahlbrecht
Cliff Cracauer
Vanessa Schultz
Ashish Gandhi
Bob Boyle